available

500100


GT 40 TT/TNS-7.5kA-S Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TT and TN-S systems

available

500101


Multi-pole compact lightning current arrester Type 1+2+3 for 3-phase TT and TN-S systems - for the 40mm busbar system - With voltage tap (L1) for the voltage supply of the APZ field - ONLY 47mm wide. - Lightning impulse current 12.5kA (10/350µs) per pole, protection level less than 1.5kV - Status indication green/not green - Leakage current free

available

500102


CT combined arrester type 1+2 for AC power supplies TT- and TNS systems -remote changeover contact -pluggable modules -for 230V/400V nominal voltage -lightning impulse current (10/350) per pole, protection level less than 1,5kV -defect indicator on plug-in module (red) -free of leakage current

available

500103


CT combined arrester type 1+2 for AC power supplies TT- and TNS systems -remote changeover contact -pluggable modules -for 230V/400V nominal voltage -lightning impulse current (10/350) per pole, protection level less than 1,5kV -defect indicator on plug-in module (red) -free of leakage current

available

500106


CT combined arrester type 1+2 for AC power supplies TT- and TNS systems -remote changeover contact -pluggable modules -for 230V/400V nominal voltage -lightning impulse current (10/350) per pole, protection level less than 1,5kV -defect indicator on plug-in module (red) -free of leakage current

available

500107


CT combined arrester type 1+2 for AC power supplies TT- and TNS systems -remote changeover contact -pluggable modules -for 230V/400V nominal voltage -lightning impulse current (10/350) per pole, protection level less than 1,5kV -defect indicator on plug-in module (red) -free of leakage current

available

500109


GT 40 TT/TNS-7.5kA-SI Multi-pole compact lightning current arrester Type 1+2+3 for TT/TNS system - for 40mm busbar system - With fused voltage tap (6.3A) for voltage supply of RfZ / APZ field according to VDE-AR-N 4100 - ONLY 47mm wide. - Lightning impulse current 7.5kA (10/350µs) per pole, protection level less than 1.5kV - Status indication green/not green - Leakage current free

available

500110


GT 40 TT/TNS-12,5kA-SI Multi-pole compact lightning current combination arrester Type 1+2+3 for TT/TNS system - for 40mm busbar system - With fused voltage tap (6.3A) for voltage supply of RfZ / APZ field according to VDE-AR-N 4100 - ONLY 47mm wide. - Lightning impulse current 12.5kA (10/350µs) per pole, protection level less than 1.5kV - Status indication green/not green - Leakage current free

not available

500111


GT 40 TNC-7,5kA-SI Mehrpoliger kompakter Blitzstrom Kombiableiter Typ 1+2+3 für das TNC-System - für das 40mm Sammelschienensystem - Mit abgesicherten Spannungsabgriff (6,3A) für die Spannungsversorgung des RfZ / APZ-Feldes nach VDE-AR-N 4100 - NUR 47mm breit. - Blitzstoßstrom 7,5kA (10/350µs) pro Pol, Schutzpegel kleiner 1,5kV - Statusanzeige grün/nicht grün - leckstromfrei

not available

500120


Cable set for the GT 40 arrester with secured voltage tap consisting of: 2 connection cables (6kV line) - Modem connection cable with 80cm - Gateway connection cable with 115cm 2 BLF 5.08 plugs 1 conductor connection terminal for the N-rail

available

500130


GTN 40 TT/TNS-7.5kA-B Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TT and TN-S systems - for the 40mm busbar system - ONLY 36mm wide. - Lightning surge current 7.5kA (10/350µs) per pole, protection level less than 1.5kV - Status display green/not green - no leakage current

available

500131


GTN 40 TT/TNS-12.5kA-B Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TT and TN-S systems - for the 40mm busbar system - ONLY 36mm wide. - Lightning surge current 12.5kA (10/350µs) per pole, protection level less than 1.5kV - Status display green/not green - no leakage current

available

500132


GTN 40 TT/TNS-7.5kA-Si Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TT and TN-S systems - for the 40mm busbar system - With fused voltage tap (6.3A) for the power supply of the RfZ / APZ field according to VDE-AR-N 4100 - ONLY 36mm wide. - Lightning surge current 7.5kA (10/350µs) per pole, protection level less than 1.5kV - Status display green/not green - no leakage current

kurzfristig verfügbar

500133


GTN 40 TT/TNS-12.5kA-Si Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TT and TN-S systems - for the 40mm busbar system - With fused voltage tap (6.3A) for the power supply of the RfZ / APZ field according to VDE-AR-N 4100 - ONLY 36mm wide. - Lightning surge current 12.5kA (10/350µs) per pole, protection level less than 1.5kV - Status display green/not green - no leakage current

available

500134


Cable set for the GTN 40 arrester with fused voltage tap consisting of: 2 connection cables (6kV line) with BLF 5.08 plug - Modem connection cable with 80cm - Gateway connection cable with 115cm

available

500135


GTN 40 E feed for the 40mm system - Max. current carrying capacity 125A - Voltage range 230/400V - Connection cross section 1-25mm² single and stranded - Lightning current resistant

available

500136


GTN 40 TNC-12.5kA-B Multi-pole compact lightning current combination arrester type 1+2+3 for 3-phase TNC systems - for the 40mm busbar system - ONLY 36mm wide. - Lightning surge current 12.5kA (10/350µs) per pole, protection level less than 1.5kV - Status display green/not green - no leakage current

available

500139


APZ connection cable set consisting of: 1x Cat.6A patch cable 6kV, 1.5m 2x Cat.6A RJ45 coupling with dust protection caps for REG installation

available

500190


Mehrfachklemme 3x 16mm² für Zusatzanschluss Steglänge 23mm VPE 20

available

500191


Mehrfachklemme 2x 25mm² für Zusatzanschluss Steglänge 17mm VPE 20